Laboratory fume hoods are essential for maintaining a safe and compliant work environment. Whether in academic research labs, industrial facilities, or pharmaceutical production, proper ventilation is critical to protecting personnel and maintaining air quality.
LOC Scientific’s laboratory fume hoods are engineered for performance, reliability, and adaptability to support safe operation in demanding lab applications. Each hood is designed to contain hazardous fumes and improve indoor air quality.
Choosing The Right Laboratory Fume Hoods
LOC Scientific’s laboratory fume hoods offer the performance, reliability, and adaptability needed for demanding lab applications. Explore our specific models below to find the perfect fit for your safety requirements.
ADA Compliance Hood
Our ADA compliance hood allows easy access without sacrificing safety or performance. These hoods meet all Americans with Disabilities Act requirements with ergonomic features. The low-profile design and clear sightlines...
Read More
Add Air Fume Hood
Our add air fume hood introduces up to 70% of the required air directly into the hood. This design helps reduce HVAC loads and conserves energy. It’s ideal for labs...
Read More
Bypass Hood
The bypass hood delivers consistent airflow to protect users during sash movement. As the sash opens or closes, the bypass system adjusts the airflow automatically. This design minimizes airflow surges...
Read More
Demonstration Hood
Offers complete visibility from all sides, making it perfect for teaching and training environments. Clear panels and...
Read More
High-Performance Hood
When your lab requires superior containment and energy savings, our high-performance hood delivers. These hoods reduce face velocity requirements and energy consumption while meeting ASHRAE 110 standards. Use them in...
Read More
Low Bench Hood
Our low bench hoods accommodate tall apparatus and provide additional vertical space. These hoods sit lower than traditional benches and support large-scale setups without compromising containment.
Read More
Perchloric Acid Hood
Perchloric acid hoods feature unique wash-down systems and non-reactive surfaces to handle highly oxidizing chemicals. The design prevents the buildup of explosive perchlorates and complies with safety guidelines for perchloric...
Read More
Portable Hood
A flexible, self-contained solution for labs requiring mobile containment. These units can be moved easily from station to...
Read More
Radio Isotope Hood
Built with stainless steel liners and reinforced construction for easy decontamination. Meets strict radiation safety guidelines...
Read More
Variable Air Volume (VAV) Hood
Adapts airflow in real-time based on sash position. These smart systems are compatible with building management... Read More
Vista Hood
Features an extended interior and oversized sash opening for maximum visibility. Ideal for collaborative work or procedures... Read More
Walk-In Hood
Full-sized enclosures providing maximum space for large apparatus, pilot plants, and heavy equipment. Designed to... Read More
Fume Hood Accessories
Customize your unit with our full range of components, including airflow monitors, exhaust fans, remote fixtures, and... Read More
Our Laboratory Fume Hoods
We offer a wide range of laboratory fume hoods to meet specific safety, performance, and design requirements. Each hood supports chemical containment and improves indoor air quality while meeting stringent lab standards. Our selection includes solutions for general use, high-performance needs, and specialized environments.
Which Laboratory Fume Hood Do You Need?
Start with the job the hood has to do. This quick guide points each common need to a hood type, and
every name links to its product page.
| If you need... | Consider |
|---|---|
| Full visibility for teaching and training | Demonstration hood or Vista hood |
| Energy savings and lower face velocity requirements | VAV hood or high-performance hood |
| Steady airflow while the sash moves | Bypass hood |
| Extra vertical space for tall apparatus | Low bench hood |
| Large apparatus, pilot plants or heavy equipment | Walk-in hood |
| Perchloric acid work | Perchloric acid hood |
| Radioactive materials | Radio isotope hood |
| Mobile containment | Portable hood |
| Accessible operation | ADA compliance hood |
Wondering whether a floor-standing unit fits your apparatus? Our walk in fume hood guide covers sizing, ducting and installation. If you are comparing a fume hood with a clean bench, see fume hood vs. laminar flow hood.
Choosing the Right Laboratory Fume Hood
Explore our hood types below. Each one links to a product page with specifications, so you can compare models and find the right fit for your safety requirements.
ADA Compliance Hood
Our ADA compliance hood allows easy access without sacrificing safety or performance. These hoods are designed to meet Americans with Disabilities Act requirements with ergonomic features. The low-profile design and clear sightlines...
Add Air Fume Hood
Our add air fume hood introduces up to 70% of the required air directly into the hood. This design helps reduce HVAC loads and conserves energy. It’s ideal for labs...
Bypass Hood
The bypass hood delivers consistent airflow to protect users during sash movement. As the sash opens or closes, the bypass system adjusts the airflow automatically. This design minimizes airflow surges...
Demonstration Hood
Our demonstration hood offers complete visibility from all sides, making it perfect for teaching and training environments. Clear panels and...
High-Performance Hood
When your lab requires superior containment and energy savings, our high-performance hood delivers. These hoods reduce face velocity requirements and energy consumption while meeting ASHRAE 110 standards. Use them in...
Low Bench Hood
Our low bench hoods accommodate tall apparatus and provide additional vertical space. These hoods sit lower than traditional benches and support large-scale setups without compromising containment.
Perchloric Acid Hood
Perchloric acid hoods feature unique wash-down systems and non-reactive surfaces to handle highly oxidizing chemicals. The design prevents the buildup of explosive perchlorates and follows safety guidelines for perchloric...
Portable Hood
A flexible, self-contained solution for labs requiring mobile containment. These units can be moved easily from station to...
Radio Isotope Hood
Built with stainless steel liners and reinforced construction for easy decontamination. Designed to meet strict radiation safety guidelines...
Variable Air Volume (VAV) Hood
Adapts airflow in real time based on sash position. These smart systems are compatible with building management...
Vista Hood
Our Vista hood features an extended interior and oversized sash opening for maximum visibility. Ideal for collaborative work or procedures...
Walk-In Hood
Our walk-in hood provides maximum space for large apparatus, pilot plants, and heavy equipment. Two independent vertical sashes let you roll in oversized equipment and portable workstations.
Fume Hood Accessories
Customize your unit with our full range of components, including airflow monitors, exhaust fans, remote fixtures, and...
How to Maintain Fume Hood
Safety in Your Laboratory
Conduct routine visual inspections of your fume hood to identify any damage, wear, or obstructions. Check for proper sash operation and ensure all safety features function correctly.
Monitor airflow indicators regularly and ensure face velocity meets safety standards. Proper airflow is critical for effective containment of hazardous fumes and vapors.
Schedule regular air volume testing to verify containment performance. Professional testing helps confirm your hood meets ASHRAE 110 and other industry standards for safe operation.
Train users on proper sash positioning and operation. Keep the sash at the lowest practical working height to maintain optimal containment.
Avoid rapid movements, keep materials inside the hood, and maintain clear airflow pathways. OSHA’s fume hood fact sheet advises keeping materials at least six inches back from the sash opening.
Conduct comprehensive annual assessments, including performance testing, calibration verification, and maintenance requirements, to ensure continued safe operation.
Our Laboratory Fume Hood Calibration Services
We offer professional fume hood calibration services that verify airflow, containment, and system responsiveness. Our technicians perform in-field testing using precise instruments to meet ASHRAE 110 and other industry standards. We schedule calibration around your workflow to minimize disruption and maintain safety compliance.
Key services include:
- In-field performance testing
- ASHRAE 110 compliance verification
- Airflow and containment validation
- System responsiveness testing
- Scheduled maintenance programs
Why Choose LOC Scientific?
LOC Scientific brings over three decades of experience to every lab environment we build. Our products are made in the USA with durable materials and built for lasting performance. We prioritize customization, fast turnaround times, and personal customer support that doesn’t stop at delivery.
Let's Begin Your Project Today
Tell us about your lab, your hazards and your apparatus, and we will recommend the right hood type. Request a design or call 770-932-0202.
Related Products
Frequently Asked Questions
A laboratory fume hood is a ventilated enclosure that protects lab personnel from hazardous gases, vapors, and chemical fumes generated during experiments or processes. Air is drawn in through the open front sash and exhausted through a duct system to the outside, preventing fumes from entering the lab. Face velocity, the speed of incoming air measured in feet per minute, is the primary metric for assessing containment performance. We supply a full range of hood types for different laboratory settings.