LOC's ADA Fume Hood is designed to meet the unique needs of wheelchair operators. The ADA Fume Hood delivers all the features and capabilities of our standard Fume Hood line with special accommodations built in to meet the specific requirements needed to provide a safe work site for wheelchair operators.
Our ADA compliant design ensures equal access to laboratory safety equipment while maintaining the high performance and reliability standards expected in professional laboratory environments. Every accommodation is thoughtfully integrated to provide seamless operation for all users.
Our ADA Compliant Fume Hood
The ADA Fume Hood combines full accessibility compliance with uncompromised safety performance. Special accommodations are seamlessly integrated into the design while maintaining all standard fume hood capabilities. This ensures wheelchair operators have equal access to safe laboratory work environments without sacrificing functionality or performance standards.
ADA Compliance & Performance Features
Wheelchair accessible design meeting ADA standards while maintaining full laboratory safety performance
Meets all ADA requirements for wheelchair operator access and safety
Optimized work surface height for comfortable wheelchair operation
Adequate knee and leg clearance for wheelchair positioning and movement
Easy-to-reach controls positioned for wheelchair operator convenience
Full safety capabilities matching standard fume hood performance levels
75, 100, and 125 FPM options to meet diverse laboratory requirements
Thoughtful design considerations for comfortable extended use
Additional modifications available to meet specific accessibility needs
ADA Hood Applications & Environments
ADA compliant fume hoods provide essential accessibility across diverse laboratory and educational environments:
- Research Institutions: Enable wheelchair-using researchers to participate fully in laboratory research with equal access to safety equipment.
- Educational Laboratories: Support inclusive education by providing accessible laboratory equipment for students and faculty with mobility challenges.
- Government Facilities: Meet federal accessibility requirements while maintaining laboratory safety standards in government research facilities.
- Healthcare Laboratories: Provide accessible workspaces for healthcare professionals requiring laboratory analysis and research capabilities.
- Industrial Quality Control: Support diverse workforce inclusion in manufacturing quality control and testing laboratories.
- Pharmaceutical Development: Enable full participation of all team members in drug development and testing procedures requiring fume hood protection.
Benefits of Choosing ADA Compliant Fume Hoods
- Full ADA Compliance: Meets all accessibility requirements ensuring equal access to laboratory safety equipment
- Uncompromised Safety: Maintains all standard fume hood safety performance while providing accessibility accommodations
- Inclusive Workplace: Enables diverse workforce participation in laboratory research and analysis activities
- Ergonomic Operation: Thoughtful design reduces strain and improves comfort for extended laboratory work sessions
- Regulatory Compliance: Satisfies federal accessibility requirements for educational and government laboratory facilities
- Flexible Performance: Multiple face velocity options accommodate various laboratory procedures and safety requirements
- Professional Integration: Seamless design integration maintains laboratory aesthetics and professional appearance
- Custom Adaptability: Additional accommodations available to meet specific individual accessibility needs
Technical Specifications & Performance Data
| Model # | Hood Size | Collar Size | 75 FPM | 100 FPM | 125 FPM | |||
| CFM | SP | CFM | SP | CFM | SP | |||
| B-684 | 48" | 10" Dia. | 325 | .05 | 433 | .09 | 542 | .13 |
| B-685 | 60" | 10" Dia. | 425 | .04 | 567 | .08 | 708 | .12 |
| B-686 | 72" | 10" Dia. | 525 | .06 | 700 | .10 | 875 | .16 |
| B-687 | 84" | 2) 10" Dia. | 625 | .05 | 833 | .08 | 1042 | .13 |
| B-688 | 96" | 2) 10" Dia. | 725 | .06 | 967 | .10 | 1208 | .16 |
ADA Compliance Features:
- Work Surface Height: Optimized for wheelchair access (typically 30"-32" AFF)
- Knee Clearance: Minimum 27" high, 30" wide, 19" deep clear space
- Control Accessibility: All controls within reach range (15"-48" AFF)
- Approach Space: Clear floor space 30" x 48" minimum for wheelchair approach
- Operating Force: Controls operable with one hand without tight grasping
Performance Features:
- Face Velocity Options: 75, 100, and 125 FPM for diverse laboratory requirements
- Airflow Performance: Consistent containment across all face velocity settings
- Safety Standards: Meets all laboratory safety requirements while providing accessibility
- Construction Quality: Same robust construction as standard fume hood line
Installation Notes:
- Static pressures listed are for hoods only; additional duct system pressure drop must be calculated
- Total pressure drop through hood and duct system determines proper exhaust blower selection
- ADA compliance requires specific installation heights and clearances per ADA guidelines
Why Choose LOC Scientific?
LOC Scientific is committed to creating inclusive laboratory environments that provide equal access to safety equipment for all users. Our ADA compliant fume hoods demonstrate our dedication to accessibility without compromising the safety and performance standards that laboratories require.
We understand that accessibility compliance is not just about meeting regulations—it's about creating opportunities for diverse participation in scientific research and analysis. Our ADA fume hoods provide the accommodations needed while maintaining the reliability and performance that make LOC Scientific a trusted laboratory partner.